BAM ýokary woltly güýç kondensatory
Programma we standartlar:
Volokary woltly kondensator esasan güýç faktoryny gowulandyrmak üçin 50Hz bilen AC Power ulgamynda ulanylýar. Öndürijiligi GB 3083.2-89 《volokary woltly şunt kondensatoryna we IEC 60871-1987 laýyk gelýär.
GB / T11024-2010 Milli standart AC AC elektrik ulgamlary üçin 1kV ýa-da ondan ýokary naprýa .eniýe kondensatorlary
JB / 7112-2000 Maşyn senagaty standarty 《Gurnalan HV Shunt kondensatory
DL / T628-1997 Elektrik energiýasy senagaty standart 《Gurnalan HV Shunt kondensatory tehniki talaplary sargyt edýär
Ulanyş şertleri:
1.Altitude: 1000 m-den az; Daşky gurşawyň temperaturasy: -40 ℃ ~ + 40 ℃。
2. Zorlukly mehaniki yrgyldy, zyýanly gaz we bug ýok, elektrik, partlaýjy we partlaýjy tozan ýok.
3. Üznüksiz işleýiş naprýa .eniýesi: 1.00 Un, uzak möhletli iň ýokary naprýa .eniýe: Artykmaç naprýa .eniýe: az.1 Un.
4. Durnukly artykmaç (şol sanda garmonika tokyny) 1,3 In.
5.Göçýän naprýa .eniýe bilen: 2.15 terminaly, 10 sekuntda kesgitlenen naprýa .eniýe, terminallar bilen 42kV konteýner arasynda 10 sekunt.
Esasy tehniki aýratynlyklar:
1. Bahalandyrylan naprýa .eniýe: 6.3kV, 6.6kV, 6.6 / √3kV, 7.96kV, 10.5kV, 11kV, 11kV, 11 / √3kV, beýleki ýörite kuwwat isleseňiz tertipde görkeziň.
2. Bahalandyrylan kuwwat: 33 ~ 334kvar, beýleki ýörite kuwwaty isleseňiz tertipde görkeziň.
3. Potensial çydamlylygy: -5 ~ 15%.
4. Angelitirilen perişde tangensial gymmaty: film we papaer orta tg θ 8 0.08%, film orta tg θ ≦ 0.05%.
5.Göçüriş naprýa .eniýesi: kuwwat aýaklarynyň arasynda AC2.15 ýa-da DC4.3 gezek bahalandyrylan naprýa .eniýäni, arakesmesiz ýa-da fleşkasyz takmynan 10s dowam edip biler, BIL: 6kV (30kV), 10kV (42Kv).
6. Mugt zarýad: içerki garşylygy bar, tok üpjünçiligini kesenden 10 minut soň, galyndy naprýa .eniýesi √2 Un-dan 75V çenli azalýar.
7.Maks. Häzirki: 1,3 gezek bahalandyrylan naprýa .eniýeniň aşagynda, naprýatageeniýeniň, kuwwatyň oňyn çydamlylygynyň we her 24 sagatda 1 minutdan geçip bilmeýän garmoniki tolkunyň aşagynda işlemegi.
8
9.Standard: GB / T 112024.1-2001, IEC6087: 1997.
Aýry-aýry faza güýç kondensatory
Model BAM | Bahalandyrylan naprýa .eniýe (kV) | Bahalandyrylan çykyş (kVAr) | Bahalandyrylan kuwwatlyk (uF) | Häzirki baha (A) |
10.5-50-1W | 10.5 | 50 | 1.444 | 4.762 |
6.35-30-1W | 6.35 | 30 | 2.368 | 4.724 |
6.35-50-1W | 6.35 | 50 | 3.946 | 7.873 |
6.3-30-1W | 6.3 | 30 | 2.4 | 4.76 |
6.3-50-1W | 6.3 | 50 | 4 | 7.9 |
6.3-100-1W | 6.3 | 100 | 8 | 15.9 |
6.3-200-1W | 6.3 | 200 | 16 | 31.7 |
6.3-300-1W | 6.3 | 300 | ýigrimi dört | 47.6 |
6.3-334-1W | 6.3 | 334 | 26.8 | 53 |
10.5-50-1W | 10.5 | 50 | 1.44 | 4.8 |
10.5-100-1W | 10.5 | 100 | 2.9 | 9.5 |
10.5-150-1W | 10.5 | 150 | 4.3 | 14.3 |
10.5-200-1W | 10.5 | 200 | 5.8 | 19 |
10.5-300-1W | 10.5 | 300 | 8.67 | 28.6 |
10.5-334-1W | 10.5 | 334 | 9.65 | 31.8 |
6.35-50-1W | 6.35 | 50 | 3.95 | 7.87 |
6.35-100-1W | 6.35 | 100 | 7.89 | 15.75 |
6.35-150-1W | 6.35 | 150 | 11.84 | 23.6 |
6.35-200-1W | 6.35 | 200 | 15.78 | 31.5 |
6.35-300-1W | 6.35 | 300 | 23.68 | 47.2 |
6.35-334-1W | 6.35 | 334 | 26.36 | 52.6 |
3.81-50-1W | 3.81 | 50 | 10.96 | 13.12 |
3.81-100-1W | 3.81 | 100 | 21.9 | 26.24 |
3.81-150-1W | 3.81 | 150 | 32.9 | 39.36 |
3.81-200-1W | 3.81 | 200 | 43.8 | 52.48 |
3.81-300-1W | 3.81 | 300 | 65.8 | 78.7 |
3.81-334-1W | 3.81 | 334 | 73.2 | 87.6 |
11-100-1W | 11 | 100 | 2.63 | 9.1 |
11-150-1W | 11 | 150 | 3.95 | 13.6 |
11-200-1W | 11 | 200 | 5.26 | 18.2 |
11-300-1W | 11 | 300 | 7.89 | 27.3 |
11-334-1W | 11 | 334 | 8.79 | 30.4 |
12-100-1W | 12 | 100 | 2.2 | 8.33 |
12-150-1W | 12 | 150 | 3.3 | 12.5 |
12-200-1W | 12 | 200 | 4.4 | 16.7 |
12-300-1W | 12 | 300 | 6.64 | 25 |
12-334-1W | 12 | 334 | 7.39 | 27.8 |
6.93-100-1W | 6.93 | 100 | 6.63 | 14.4 |
6.93-150-1W | 6.93 | 150 | 9.95 | 21.7 |
6.93-200-1W | 6.93 | 200 | 13.3 | 28.9 |
6.93-300-1W | 6.93 | 300 | 19.9 | 43.3 |
6.93-334-1W | 6.93 | 334 | 22.1 | 48.2 |
6.93-400-1W | 6.93 | 400 | 26.54 | 57.74 |
6.3-100-1W | 6.3 | 100 | 8 | 15.9 |
6.3-150-1W | 6.3 | 150 | 12 | 23.8 |
6.3-200-1W | 6.3 | 200 | 16 | 31.7 |
6.3-300-1W | 6.3 | 300 | ýigrimi dört | 47.6 |
6.3-334-1W | 6.3 | 334 | 26.8 | 53 |
6.6-100-1W | 6.6 | 100 | 7.3 | 15.2 |
6.6-150-1W | 6.6 | 150 | 11 | 22.7 |
6.6-200-1W | 6.6 | 200 | 14.6 | 30.3 |
6.6-300-1W | 6.6 | 300 | ýigrimi iki | 45.5 |
6.6-334-1W | 6.6 | 334 | 24.4 | 50.6 |
3.81-100-1W | 3.81 | 100 | 21.9 | 26.24 |
3.81-150-1W | 3.81 | 150 | 32.9 | 39.36 |
3.81-200-1W | 3.81 | 200 | 43.8 | 52.48 |
3.81-300-1W | 3.81 | 300 | 65.8 | 78.7 |
3.81-334-1W | 3.81 | 334 | 73.2 | 87.6 |
6.35-100-1W | 6.35 | 100 | 7.89 | 15.75 |
6.35-150-1W | 6.35 | 150 | 11.84 | 23.6 |
6.35-200-1W | 6.35 | 200 | 15.78 | 31.5 |
6.35-300-1W | 6.35 | 300 | 23.68 | 47.2 |
6.35-334-1W | 6.35 | 334 | 26.36 | 52.6 |
11-100-1W | 11 | 100 | 2.63 | 5.25 |
11-150-1W | 11 | 150 | 3.95 | 7.87 |
11-200-1W | 11 | 200 | 5.26 | 10.5 |
11-300-1W | 11 | 300 | 7.9 | 15.75 |
11-100-1W | 11 | 100 | 2.63 | 5.25 |
11-150-1W | 11 | 150 | 3.95 | 7.87 |
11-200-1W | 11 | 200 | 5.26 | 10.5 |
11-300-1W | 11 | 300 | 7.9 | 15.75 |
12-100-1W | 12 | 100 | 2.2 | 4.8 |
12-150-1W | 12 | 150 | 3.3 | 7.2 |
12-200-1W | 12 | 200 | 4.4 | 9.6 |
12-300-1W | 12 | 300 | 6.64 | 14.45 |
12-100-1W | 12 | 100 | 2.2 | 4.8 |
12-150-1W | 12 | 150 | 3.2 | 7.2 |
12-200-1W | 12 | 200 | 4.4 | 9.6 |
12-300-1W | 12 | 300 | 6.64 | 14.45 |
11 / √3-200-1W | 11 / √3 | 200 | 15.78 | 31.5 |
11 / √3-334-1W | 11 / √3 | 334 | 26.36 | 52.6 |
12 / √3-200-1W | 12 / √3 | 200 | 13.3 | 28.9 |
12 / √3-334-1W | 12 / √3 | 334 | 22.1 | 48.2 |
12-200-1W | 12 | 200 | 4.4 | 16.7 |
12-334-1W | 12 | 334 | 7.39 | 27.8 |
10.5-200-1W | 10.5 | 200 | 5.8 | 19 |
10.5-334-1W | 10.5 | 334 | 9.65 | 31.8 |